The CA-FIRE automatic positioning fire monitor is a complete automatic tracking & positioning jet fire-extinguishing system. Using infrared and ultraviolet sensors, it detects the radiation released by a fire, scans the protected 3D space, drives the nozzle precisely onto the fire source, then automatically opens the valve, starts the pump and discharges — extinguishing a fire in its earliest stage with no human input.

The system combines the monitor, a field control box, a central control cabinet and an Ethernet AI management platform with HD camera — delivering long detection range, large coverage area, high sensitivity, fast response and full-area monitoring with no blind spots.

IR / UV Detection Ethernet AI System Auto-Targeting
5–50
Flow Rate (L/s)
73 m
Max Jet Radius
360°
Horizontal Swing
Ex
Explosion-Proof Option

How Automatic Positioning Works

01
Detect
Infrared / ultraviolet flame detectors continuously monitor the protected space for a fire signature.
02
Locate
On detection, the system calculates the fire's position (horizontal and vertical coordinates) within the coverage area.
03
Aim
The monitor automatically drives to the calculated position, pointing the nozzle directly at the fire source.
04
Suppress
Linked to the fire alarm and control panel, the monitor discharges water or foam onto the fire — fully automatically.

Product Video — Automatic Positioning in Action

Watch the CA-FIRE automatic positioning fire monitor detect, target and discharge.

Key Features

Ethernet AI Management System
In-house developed Ethernet AI platform combines live video and control in one interface. Fire-alarm, automatic and manual operation logs are displayed centrally — one-click remote control of any field monitor.
IR / UV Flame Positioning
New digital-filter algorithm for accurate location and strong interference rejection. The system displays the flame-intensity value during scanning, and AI-assisted calibration corrects positioning error automatically.
2-Megapixel HD Digital Camera
200W (2 MP) digital camera versus the 30W analogue cameras used by conventional makers — higher clarity and strong anti-interference, eliminating "snow-screen" noise.
32-Microstep Smooth Drive
The turret motor uses a 32-microstep algorithm for smoother rotation and higher aiming precision onto the fire source.
Single-Fibre Wiring Saves Cost
Integrated remote Ethernet management runs field-to-control-room on a single optical fibre (video + control combined), removing a separate comms line and greatly cutting cabling cost versus traditional CAN / RS-485.
Auto Device Recognition
The field control box automatically recognises and adds connected monitors, with one-click multi-device synchronisation of height and sensitivity settings for fast commissioning.

System Components

Automatic Positioning Monitor
Stainless steel SS304/SS316 monitor with IR/UV flame detector, HD camera and motorised pan/tilt — detects, tracks and discharges onto the fire.
Field Control Box (ZDMAN-NX)
Wall-mounted box with LCD display — powers the field devices, relays signals between monitor and central host, allows local manual operation and outputs the alarm interlock signal.
Central Control Cabinet (ZDM-ZK01)
Floor-standing cabinet in the fire control room — Ethernet networking of multiple field boxes, backup-power management, system power output and video management.
Junction Box & Wiring
Each monitor connects through a junction box; CAN H/L terminals must correspond (do not reverse). Field-to-control-room runs on a single optical fibre.

System Architecture

Fire Monitor + IR/UV detector + HD camera Junction Box Field Control Box ZDMAN-NX 220VAC · LCD CAN bus · alarm out Central Cabinet ZDM-ZK01 Ethernet AI host video + control power + CAN single fibre Fire alarm host + pump control panel

System architecture: each monitor links through a junction box to the field control box (ZDMAN-NX), which connects to the central control cabinet (ZDM-ZK01) in the fire control room over a single optical fibre. Field control box outputs the fire-alarm interlock and pump-control signals. CAN H/L terminals must correspond — do not reverse.

Installation & Wiring Diagram
FIELD CONTROL BOX ZDMAN-NX · 220VAC 50Hz · LCD · CAN bus power switch LNPEP-LP-NPE HLalarmpumpfb power / device terminals CAN · alarm · pump terminals FIRE EXTINGUISHING DEVICE Automatic positioning monitor + IR/UV detector + HD camera JUNCTION BOX — INTERNAL TERMINALS LNPE HL +cam 220V CAN camera junction box CAN comms WDZN-RYSP 2×1.0mm² Power WDZN-RVV 3×1.0mm² input mod. Fire alarm control panel Alarm interlock out (volt-free NO) WDZN-RVV 2×1.0mm² Monitor pump control cabinet Pump control & pump-on feedback WDZN-RVV 4×1.0mm² 220VAC device power supply WDZN-RVV 3×2.5mm²
WDZN-RYSP 2×1.0mm² — CAN communication line
WDZN-RVV 3×1.0mm² — Power line (box ↔ monitor)
WDZN-RVV 2×1.0mm² — Fire alarm interlock (volt-free NO)
WDZN-RVV 4×1.0mm² — Pump control & feedback
WDZN-RVV 3×2.5mm² — 220VAC device power (mains in)
Note: CAN line H and L terminals must correspond — do not reverse. Field control box is wall-mounted 1.2–1.5 m above floor. For multi-device runs, connect CAN in a daisy-chain (hand-to-hand) configuration. Confirm final wiring against project documentation.

ZDMS Automatic Fire Monitor Models

The CA-FIRE ZDMS series automatic positioning fire monitors are available in four configurations — standard water, foam-water, explosion-proof water and explosion-proof foam-water — with flow rates from 5 to 50 L/s, jet radius up to 73 m and 360° horizontal coverage.

ZDMS automatic positioning water fire monitor standard model
Water
Standard Water (ZDMS-S)
Standard automatic water monitor, 5–50 L/s, jet radius up to 73 m. For warehouses, atriums and large indoor spaces.
ZDMS automatic positioning foam water fire monitor
Foam-Water
Foam-Water (ZDMS-P)
Automatic foam-water monitor, 30–50 L/s, foaming ratio ≥6. For petroleum, solvent and Class B hazard areas.
ZDMS explosion proof automatic positioning water fire monitor
Explosion-Proof
Explosion-Proof Water (ZDMS-S-Ex)
Ex d IIB/IIC T4 Gb, IP65–67. 20–50 L/s for hazardous areas — tank farms, LNG terminals, chemical plants.
ZDMS explosion proof automatic positioning foam water fire monitor
Explosion-Proof Foam
Explosion-Proof Foam (ZDMS-P-Ex)
Ex-rated foam-water monitor, 30–50 L/s, foaming ratio ≥6. Class B suppression in classified hazardous zones.
Water Standard Water Monitor — ZDMS-S
ModelZDMS0.6/5SZDMS0.6/10SZDMS0.8/20SZDMS0.8/30SZDMS0.8/40SZDMS0.8/50S
Flow Rate ±8% (L/s)51020304050
Working Pressure (MPa)0.60.60.80.80.80.8
Jet Radius (m)343956626773
Max Protection Radius (m)303550556065
Monitoring Radius (m)404065657070
Installation Height (m)6–206–258–358–358–358–35

Positioning time ≤30 s (5/10S) / ≤60 s · Working voltage DC12–24V · Horizontal swing 360° · Vertical −90° to +30° · Working temp −10 to +50°C · Flange G1¼" or DN80/DN100 GB/T9119-2000.

Foam-Water Foam-Water Monitor — ZDMS-P
ModelZDMS0.8/30PZDMS0.8/40PZDMS0.8/50P
Flow Rate ±8% (L/s)304050
Working Pressure (MPa)0.80.80.8
Jet Radius (m)505662
Max Protection Radius (m)455055
Monitoring Radius (m)657070
Foaming Ratio (20°C)≥6≥6≥6
Mixture Ratio6–7%6–7%6–7%

25% drainage time ≥150 s · Positioning ≤60 s · 24VDC · Installation height 8–35 m · 360° swing · −90° to +30° · −10 to +55°C · DN80/DN100 flange · Turning radius 700 mm.

Explosion-Proof Explosion-Proof Water — ZDMS-S-Ex
ModelZDMS0.8/20S-ExZDMS0.8/30S-ExZDMS0.8/40S-ExZDMS0.8/50S-Ex
Flow Rate ±8% (L/s)20304050
Working Pressure (MPa)0.80.80.80.8
Jet Radius (m)56626773
Max Protection Radius (m)50556065
Monitoring Radius (m)65657070

Explosion-proof class: Ex d IIB T4 Gb IP65–67 / Ex d IIC T4 Gb IP65–67 · Positioning ≤60 s · DC24V · Installation height 8–35 m · 360° swing · −90° to +30° · −10 to +55°C · DN80/DN100 flange · Turning radius 600 mm.

Explosion-Proof Foam Explosion-Proof Foam-Water — ZDMS-P-Ex
ModelZDMS0.8/30P-ExZDMS0.8/40P-ExZDMS0.8/50P-Ex
Flow Rate ±8% (L/s)304050
Working Pressure (MPa)0.80.80.8
Jet Radius (m)505662
Max Protection Radius (m)455055
Monitoring Radius (m)657070
Foaming Ratio (20°C)≥6≥6≥6
Mixture Ratio6–7%6–7%6–7%

Explosion-proof class: Ex d IIB T4 Gb IP65–67 / Ex d IIC T4 Gb IP65–67 · 25% drainage time ≥150 s · Positioning ≤60 s · DC24V · 8–35 m · 360° swing · −90° to +30° · −10 to +55°C · DN80/DN100 flange · Turning radius 800 mm.

Control System Parameters

Field Control Box — ZDMAN-NX
Working Voltage220VAC 50Hz
CommunicationField CAN bus · remote Ethernet
Dimensions250 × 180 × 80 mm
MountingWall, 1.2–1.5 m above floor
Central Control Cabinet — ZDM-ZK01
Working Voltage220VAC 50Hz
CommunicationEthernet
Dimensions950 × 600 × 1280 mm
InstallationFloor-standing in fire control room

The ZDMS monitor models above are matched to the ZDMAN-NX field control box and ZDM-ZK01 central cabinet. Detector count, coverage layout and mounting height are confirmed per project — contact CA-FIRE with your area dimensions and hazard class.

Applications

📦
Warehouses & Logistics
High-bay storage and logistics centres where sprinklers cannot reach the seat of a fire from the ceiling.
🏛️
Public & Commercial Spaces
Exhibition centres, airport terminals, railway stations, stadiums, theatres, shopping centres, hospitals and hotels — large indoor spaces needing automatic protection.
✈️
Hangars & Industrial
Aircraft hangars, factories and other high-ceiling structures requiring rapid, automatic, unmanned fire suppression.

Frequently Asked Questions

What is an automatic positioning fire monitor?
An intelligent fire monitor that detects, locates and targets a fire automatically using integrated flame detection, then links to the fire alarm system to discharge water or foam with no human input. It is designed for automatic protection of large-space and high-bay areas.
How is it different from a remote control fire monitor?
A remote control fire monitor is aimed and discharged by a person from a distance. An automatic positioning monitor needs no operator — it detects the fire, calculates the location, aims itself and discharges automatically.
Where is an automatic positioning fire monitor used?
Large-space and high-bay areas where a fire could start anywhere and rapid unmanned response is needed: warehouses, logistics centres, atriums, exhibition halls, stadiums and aircraft hangars.
What detection technology does it use?
Infrared and/or ultraviolet flame detection to identify and locate the fire source, then drives the monitor to the calculated position. The system integrates with the building fire alarm and control panel.
Can it discharge foam?
Yes — available in both water and foam-water configurations for Class A and Class B hazards. Flow rate and coverage are configured to the protected area per project.

Other Fire Monitor Types

Get a Quote — Fire Monitor
Manual Tiller · Gear · Remote Control · Automatic · Water & Foam · 1,200–4,800 LPM
Straight Stream / Fog / Stacked-Tip · SS304/316 · BS4504 / ANSI 150 / GB · Factory-Direct · 50+ Countries · ISO 9001
sales@ca-fire.com ⊙ WhatsApp: +86 18150362095 +86 13400715622 ⊙ WeChat: 404863577
Send Inquiry →
Scroll to Top