Fire Monitor Base — PZ Series Flanged Pipe Base, DN100/DN150, PN1.6
PZ Series · Self-draining · Anti-collision · Pressure-regulating · Standard / Gear-driven / Multi-function · Compatible with all PS & PL monitors
PZ Series
The Foundation of Every Fixed Monitor Installation — Self-Draining, Anti-Collision, Pressure-Regulating
The CA-FIRE PZ Series is the flanged pipe base that connects the water supply main to the PS or PL Series fire monitor above. It provides a stable structural mounting point on the pipe riser, the rotating bearing joint that allows the monitor to rotate 360° horizontally, and — depending on the variant — automatic self-draining, anti-collision protection, pressure regulation, and multi-function hose brigade connection.
Three variants cover the full range of installation requirements: the standard self-draining base for general outdoor fixed installations, the gear-driven anti-collision pressure-regulating base for exposed or high-risk locations, and the multi-function base for sites that also require a fire brigade hose connection at the same riser point. All variants accept DN100 or DN150 flanged inlets and are rated to PN1.6 MPa for water and foam-water mixed media.
- Compatible with all CA-FIRE PS and PL Series monitors — standard DN100 monitor outlet interface
- Automatic self-draining when monitor shuts off — prevents freeze damage to base and lower monitor
- Three variants: standard, gear-driven anti-collision / pressure-regulating, and multi-function
- DN100 or DN150 flanged inlet — matches supply main pipe size
- Rated PN1.6 MPa for water and foam-water mixed media
- Live-piston self-drain valve — seals under pressure, opens automatically at shut-off
- Adjustable installation height — above-ground stem length customised to project requirements
Three PZ Series Variants — Choose the Right Base for Your Installation
Technical Specifications — PZ Series Fire Monitor Base
| Product Series | Model | Nominal Pressure (MPa) | Inlet Type | Inlet Diameter | Takewater Inlet | Monitor Outlet | Hose Outlets | Auto-Drain | Media |
|---|---|---|---|---|---|---|---|---|---|
| Standard Self-Draining Base | |||||||||
| Fire Monitor Base | PZ100-1.6 | 1.6 | Flanged | DN100 | — | DN100 | — | Yes | Water / Foam-Water |
| PZ150-1.6 | DN150 | ||||||||
| Gear-Driven Anti-Collision & Pressure-Regulating Base | |||||||||
| Fire Monitor Base (Gear-Driven) |
PZ100-1.6C | DN100 | — | — | |||||
| PZ150-1.6C | DN150 | ||||||||
| Multi-Function Base | |||||||||
| Multi-Function Monitor Base |
PZ100-1.6D | 1.6 | Flanged | DN100 | M125×6 | DN100 | 2× KWS65 | Yes | Water / Foam-Water |
| PZ150-1.6D | DN150 | ||||||||
† Above-ground stem height is customisable to project requirements. Specify required height when ordering. Custom pressure-regulating, anti-collision and foam injection variants available on request for all series.