Ca fire protection factory

Products

Russian Standard Above-Ground Fire Hydrant — GOST 24013-80 | CA-FIRE

✓ GOST 24013-80 Compliant
✓ DN100 · 1.0 MPa
✓ −40°C Frost Resistant
✓ Ductile Iron Body
✓ Auto-Drain after Use
✓ 20+ Year Service Life
✓ ISO 9001 · CE · GOST

The CA-FIRE Russian standard above-ground fire hydrant is manufactured to GOST 24013-80 — the Russian national standard for outdoor fire hydrants — and is designed specifically for Russia’s extreme climate conditions, from −40°C northern winters to +60°C summer operating temperatures. The DN100 pillar hydrant provides a maximum flow rate of 90 L/s at 1.0 MPa working pressure through two GOST-thread outlets (100 mm main + 65 mm auxiliary), connecting directly to Russian standard PN10/PN16 flanged water mains. A built-in frost-proof valve core and automatic drain system expel residual water after each use, preventing barrel freeze and cracking without any manual intervention. Ductile iron body construction (EN-GJS-450-10) with hot-dip galvanising and RAL 3000 red powder coating provides 20+ years of service life in industrial and municipal installations across Russia and the CIS.

Technical Specifications — GOST 24013-80

Parameter Specification
Compliance Standard GOST 24013-80 · ISO 9001:2015 · CE
Nominal Diameter DN100 (100 mm / 4 inch)
Working Pressure 1.0 MPa (145 psi)
Test Pressure (Hydrostatic) 1.5 MPa — 30-minute hold, zero leakage
Maximum Flow Rate 90 L/s (1,422 GPM)
Outlet Configuration 1 × 100 mm main outlet + 1 × 65 mm auxiliary outlet (GOST standard threads)
Connection (Inlet) Flange — PN10/PN16, GOST standard flange dimensions
Body Material Ductile iron EN-GJS-450-10
Valve Core Material Brass alloy Cu-Zn 40
Sealing Material EPDM rubber · temperature range −40°C to +80°C
Surface Treatment Hot-dip galvanising (Zn ≥ 90 μm) + electrostatic powder coating RAL 3000 red (customisable)
Frost Protection Auto-drain system — expels residual water after use; operating range −40°C to +60°C
Overall Height 1,200 mm (excluding flange base)
Net Weight 95 kg (without accessories)
Standard Accessories 2 × hydrant caps · 1 × operating wrench · 1 × flange gasket · 4 × fixing bolts · drain valve
Optional Accessories Thermal insulation jacket · reflective markers · GPS tracking device
Service Life 20+ years
Warranty 2 years

* Surface colour customisable: RAL 5010 blue, RAL 7035 grey, or to project specification. Thermal insulation jacket recommended for regions below −30°C.

Key Features

🌡️ −40°C Frost Resistance — Auto-Drain Design

Russia’s extreme winters demand more than standard hydrant construction. The Russian standard fire hydrant‘s frost-proof valve core and automatic drain system expel all residual water from the barrel and outlets after each use — with no manual draining required. This eliminates the primary cause of cold-weather hydrant failure: ice expansion cracking the valve body.

The ductile iron body’s thick-wall design provides additional thermal mass, slowing temperature drop in sub-zero conditions. For installations in regions below −30°C, an optional polyurethane foam insulation jacket is available.

Auto-Drain · −40°C to +60°C

🏗️ Ductile Iron Body — 20+ Year Service Life

The hydrant body is cast from ductile iron EN-GJS-450-10 — a material that combines the corrosion resistance of grey iron with the impact toughness of steel. In industrial and municipal installations exposed to vehicle impact, heavy machinery and harsh weathering, ductile iron maintains structural integrity where grey iron fractures.

Double surface protection — hot-dip galvanising (Zn ≥ 90 μm) underneath electrostatic powder coating — provides two independent corrosion barriers, extending exterior service life even in chemically aggressive industrial environments.

EN-GJS-450-10 · Zn ≥ 90μm · 20yr+

🔧 GOST-Compatible Outlets — Direct Hose Connection

Both outlet ports — the 100 mm main outlet and the 65 mm auxiliary outlet — are machined to GOST standard thread profiles, ensuring direct compatibility with Russian fire service hose couplings and fittings without adaptors. The brass alloy (Cu-Zn 40) valve core and EPDM sealing rings provide leak-free shut-off across the full −40°C to +80°C service temperature range.

The flange inlet is dimensioned to GOST PN10/PN16 standards, enabling direct bolt-up to Russian standard water main pipework during installation — no adaptor flanges or special fittings required.

GOST Thread · 100mm + 65mm · Cu-Zn40

📋 Full GOST 24013-80 Certification

Every Russian standard fire hydrant shipped by CA-FIRE is tested against the full GOST 24013-80 parameter set — working pressure, flow rate, hydrostatic test pressure, frost resistance, sealing performance and material verification — by accredited third-party testing institutions.

Each unit is accompanied by a GOST certification document, quality inspection report and bilingual installation manual (Russian and English). This documentation package enables straightforward authority submission and project handover in Russia and CIS countries.

GOST 24013-80 · ISO 9001 · CE · Test Reports

How the Russian Standard Fire Hydrant Works

The Russian standard above-ground fire hydrant uses a direct-lift valve mechanism operated by a top-mounted wrench port. The auto-drain system is passive — no powered components, no manual steps.

1

Standby — Barrel dry, auto-drain open

In standby, the main valve is closed and the drain port at the base of the barrel is open to atmosphere. Any residual water or condensation drains out through the drain port — the barrel above the valve is dry. Ice cannot form and crack the body.

2

Activation — Open valve, drain closes automatically

Insert the operating wrench into the top port and rotate clockwise. As the main valve lifts open, the mechanical linkage simultaneously closes the drain port. Water flows from the main under pressure up through the barrel to the outlets. No power, no electronics — fully mechanical.

3

Discharge — 100 mm main or 65 mm auxiliary outlet

Connect the fire hose to the appropriate outlet — 100 mm for high-flow large-diameter hose (maximum 90 L/s); 65 mm for standard fire service hose. Both outlets use GOST-standard thread profiles for direct coupling to Russian fire service equipment.

4

Shutdown — Drain reopens, barrel self-empties

Rotate the wrench anti-clockwise to close the main valve. The drain port reopens simultaneously and gravity-drains all residual water from the barrel through the drain hole at the base — leaving the barrel dry within minutes. No manual draining required in sub-zero conditions.

Installation Guide

Pre-Installation Checklist

Before installing the Russian standard fire hydrant, verify the following: the product model and GOST certification match the project specification; the hydrant shows no transport damage (check body, outlets and flange face); all standard accessories are present; the base is flat, stable and has sufficient bearing capacity (≥ 250 kg); clearance of at least 2 metres exists around the hydrant for fire tender access; the water supply pipeline is rated for 1.0 MPa working pressure and the flange face has been cleaned of rust and debris.

Installation Steps

Place the hydrant on the prepared concrete base and use a level gauge to confirm verticality (tolerance ≤ 3 mm/m). Install the EPDM flange gasket between the hydrant inlet flange and the water main flange, align all bolt holes, insert fixing bolts and tighten in a crisscross pattern to 50–60 N·m torque — even clamping force ensures a leak-free seal. Fix the hydrant to the base with M18 × 120 mm expansion bolts. Test the drain valve by hand to confirm free movement. Conduct a hydrostatic test: cap both outlets, connect the test line, pressurise slowly to 1.5 MPa and hold for 30 minutes — inspect the flange joint, valve core, drain valve and outlets for any leakage. Install reflective markers or insulation jacket if specified.

Emergency Operation

Remove the outlet cap(s) by rotating anti-clockwise. Connect fire hose to the required outlet and tighten. Insert the operating wrench into the top port and rotate clockwise to open — water flows immediately. Adjust valve opening to control flow rate. After suppression: close the valve by rotating anti-clockwise, disconnect hoses, replace outlet caps. The drain system will self-empty the barrel automatically — verify drain is functioning freely before leaving the hydrant in cold conditions.

Maintenance Schedule

Frequency Task
Monthly Inspect body, outlets and surface coating for corrosion, mechanical damage or paint loss. Confirm outlet caps are secure and undamaged. Verify drain valve moves freely. Clear any obstacles (vehicles, debris, vegetation) within the 2 m access zone. Confirm the hydrant is visible and unobstructed.
Quarterly Remove outlet caps and inspect EPDM sealing rings — replace with CA-FIRE genuine parts if cracked or deformed. Apply lubricating oil to the valve core operating port. Clean the drain valve port to remove sediment. Check flange bolts for loosening and re-torque if necessary.
Annual Conduct a full hydrostatic test (1.5 MPa, 30 minutes). Inspect the drain valve mechanism for wear. Repaint any areas where coating has failed. Check the insulation jacket for damage if installed. Verify GOST certification and maintenance log are up to date. Document all findings.
Before winter Confirm auto-drain is fully functional — operate the hydrant with no hose attached and verify water drains completely within 3 minutes of closing. Install thermal insulation jacket if region forecast is below −30°C. Mark hydrant position with snow poles if the hydrant may be obscured by snow accumulation.

Applications

Municipal Road Networks — Russia & CIS

Urban and suburban road networks, residential district perimeters and public spaces. The GOST 24013-80 pillar hydrant is the standard specified by Russian municipalities and civil construction authorities for new road infrastructure and urban renovation projects.

Oil, Gas & Industrial Plants

Refinery perimeters, compressor stations, oil field infrastructure and metallurgical plants across Russia, Kazakhstan and Siberia — environments that combine extreme cold, vehicle traffic risk and corrosive atmospheres. The ductile iron body and double-layer surface treatment are specified for exactly these conditions.

Commercial & Public Facilities

Shopping centres, hotels, airports, railway stations and hospitals in Russian cities. The hydrant’s compact footprint fits standard pavement and car park perimeters; GOST compliance satisfies Russian building code and fire authority inspection requirements for these occupancies.

Residential Communities

Residential blocks, housing estates and rural settlements. The 20+ year service life and minimal maintenance requirements make the hydrant suitable for residential environments where annual authority inspection is the primary maintenance event.

Northern & Siberian Locations

Locations experiencing sustained temperatures below −30°C — Yakutia, Norilsk, Magadan and similar environments where standard hydrant designs fail within one or two winter cycles. The auto-drain + optional insulation jacket combination ensures year-round operability.

CIS Export Projects

Belarus, Kazakhstan, Ukraine, Uzbekistan, Azerbaijan and other CIS states that share GOST standards with Russia. CA-FIRE supplies to fire protection contractors and municipal engineering bureaus across the CIS region with GOST documentation packages that satisfy local authority requirements in each market.

Frequently Asked Questions

What does GOST 24013-80 specify for above-ground fire hydrants?

GOST 24013-80 is the Russian national standard governing outdoor above-ground fire hydrants. It specifies minimum working pressure (1.0 MPa), hydrostatic test pressure (1.5 MPa for 30 minutes), flow rate performance, flange and outlet thread dimensions, frost resistance requirements (operability to −40°C), body material grades, surface treatment requirements and marking. All CA-FIRE Russian standard fire hydrants are tested against every parameter in GOST 24013-80 by accredited third-party laboratories and supplied with the test certification documentation.

How does the auto-drain system prevent freezing in Russian winters?

The auto-drain is a mechanically linked drain port at the base of the hydrant barrel, positioned below the main valve seat. When the main valve is closed, the drain port opens automatically via a linked valve mechanism, allowing residual water in the barrel above the valve to drain out by gravity through the base drain. The barrel is left dry — no standing water is present to freeze and expand. The system requires no manual operation and no electrical power. After closing the hydrant, the barrel self-empties completely within 2–3 minutes under normal conditions. For extreme cold (below −30°C), the optional insulation jacket is recommended as an additional measure.

Is the Russian standard fire hydrant compatible with other GOST-market countries?

Yes. GOST standards are adopted — in identical or slightly adapted form — by most CIS member states including Belarus, Kazakhstan, Uzbekistan, Azerbaijan, Armenia, Georgia and Ukraine. The GOST 24013-80 flange dimensions (PN10/PN16), outlet thread profiles and hydrant height are standard across these markets. CA-FIRE supplies to fire protection contractors and municipal engineering bureaus throughout the CIS region; GOST certification documentation issued with each order satisfies local authority inspection requirements in all of these markets.

What surface colour options are available?

The standard colour is RAL 3000 red — the colour specified in GOST 24013-80 for above-ground fire hydrants in Russia. Alternative colours available on request include RAL 5010 blue (used in some CIS municipalities), RAL 7035 grey (industrial and low-visibility preference) and custom RAL colours to project specification. All colours are applied as electrostatic powder coating over hot-dip galvanised substrate — the galvanising layer remains intact regardless of the top coat colour choice.

What is the difference between the Russian standard and BS750 / French type fire hydrants?

The three types use different outlet thread profiles, flange dimensions and overall height dimensions specified by their respective national standards — they are not interchangeable. Russian GOST 24013-80 uses metric thread profiles on both outlets and GOST PN10/PN16 flanges. BS750 (UK standard) uses 2½″ instantaneous coupling connectors. French NF type uses a 100 mm single outlet with French standard coupling. Always confirm which standard applies to your project authority jurisdiction before specifying — selecting the wrong standard type results in incompatibility with local fire service hose connections.

Why Specify CA-FIRE’s Russian Standard Fire Hydrant

✓ Deep GOST Expertise — Not a General Catalogue Item

CA-FIRE’s engineering team has specialised in GOST standard fire protection equipment for the Russian and CIS market for over a decade. The Russian standard fire hydrant is a dedicated engineered product — not a re-labelled general export item. GOST 24013-80 compliance is verified by accredited third-party testing, not self-declared.

✓ Complete Documentation for Authority Submission

Every order is supplied with the full documentation package: GOST certification, third-party test reports, quality inspection records and bilingual (Russian / English) installation manual. This package is designed to pass Russian and CIS fire authority inspection without additional verification requests.

✓ Factory-Direct Pricing — Single Units to Container Loads

CA-FIRE manufactures and ships directly from the factory — no distributor margin between production and your project. Competitive pricing available for single-unit project orders through to full container loads for large municipal and industrial supply contracts. Lead time and pricing confirmed within one business day of enquiry.

✓ 50+ Countries Supplied · ISO 9001 Certified

ISO 9001 certified manufacturing and over a decade of supply to fire protection contractors in Russia, Kazakhstan, Belarus, Uzbekistan and other CIS markets — alongside delivery of fire protection products to 50+ countries globally. References available for comparable GOST standard supply projects on request.

Related Products

BS750 · UK & Commonwealth

BS750 Above-Ground Fire Hydrant

British Standard BS750 pillar hydrant with 2½″ instantaneous coupling outlets. For UK, Australia, South Africa and Commonwealth market projects.

View BS750 Hydrant →

French NF · Francophone Markets

French Type Above-Ground Fire Hydrant

French NF standard pillar hydrant with 100 mm single outlet and French coupling. For France, Francophone Africa and Middle East projects.

View French Hydrant →

All Types · Full Range

Fire Hydrant — Category Overview

Compare all CA-FIRE fire hydrant types — Russian, BS750, French, GB above-ground, underground and foam series — with full specification comparison table.

View All Fire Hydrants →

Get a Quote — Russian Standard Fire Hydrant

GOST 24013-80 · DN100 · 1.0 MPa · −40°C · Ductile Iron · Factory Direct · Bilingual Documentation

sales@ca-fire.com

WhatsApp: +86 18150362095

+86 13400715622

WeChat: 404863577

Send Inquiry →

Item
Specification
Product Name
Russian Standard Aboveground Fire Hydrant
Compliance Standard
GOST 24013-80, ISO 9001:2015, CE Certification
Nominal Diameter
100mm (4 inches)
Working Pressure
1.2MPa (174 psi)
Test Pressure (Hydrostatic)
1.8MPa (261 psi) (30-minute holding time)
Maximum Flow Rate
90L/s (1422 GPM)
Outlet Configuration
1 x 100mm main outlet, 1 x 65mm auxiliary outlet (GOST standard threads)
Body Material
Ductile Iron EN-GJS-450-10
Valve Core Material
Brass Alloy (Cu-Zn 40)
Sealing Material
EPDM Rubber (-40°C ~ +80°C temperature resistance)
Surface Treatment
Hot-Dip Galvanizing (Zn ≥ 90μm) + Electrostatic Powder Coating (RAL 3000 Red, customizable)
Installation Method
Flange Connection (PN10/PN16, GOST standard flange)
Operating Temperature
-40°C ~ +60°C
Overall Height
1200mm (excluding flange base)
Net Weight
95kg (without accessories)
Standard Accessories
2 x Hydrant Caps, 1 x Operating Wrench, 1 x Flange Gasket, 4 x Fixing Bolts, Drain Valve
Optional Accessories
Thermal Insulation Jacket, Reflective Markers, GPS Tracking Device
Warranty Period
2 Years