Ca fire protection factory

Products

CHSAK-Z161-68°C Q3 Industrial Sprinkler – Top-Tier Industrial Fire Sprinkler for Special Applications

When it comes to fire protection in non-warehouse high-risk industrial settings, a reliable industrial sprinkler is a critical investment. CA-Fire Protection, a leading fire safety equipment manufacturer with over a decade of expertise, proudly presents the CHSAK-Z161-68°C Q3 non-warehouse special application industrial fire sprinkler—a precision-engineered industrial sprinkler head designed to deliver exceptional fire suppression performance for non-warehouse industrial facilities. Our CHSAK-Z161-68°C Q3 industrial sprinkler stands out for its specialized fire control capabilities, adaptability to complex industrial environments, and compliance with global safety standards, making it the preferred choice for major projects worldwide. As a one-stop fire protection solution provider, CA-Fire’s industrial sprinkler products are part of a comprehensive portfolio that includes foam fire extinguishing systems, fire alarm valves, and intelligent fire hydrants, all crafted to safeguard life and property with uncompromising quality.

What is the CHSAK-Z161-68°C Q3 Non-Warehouse Special Application Industrial Sprinkler?

The CHSAK-Z161-68°C Q3 is a high-performance non-warehouse special application industrial sprinkler (industrial fire sprinkler) engineered specifically for fire protection in non-warehouse industrial settings that require specialized fire suppression. Unlike standard sprinklers, this industrial sprinkler head features a unique design with large flow rates, specialized water distribution patterns, and advanced thermal sensitivity, making it ideal for environments where fire risks are heightened but do not fit the typical warehouse high-rack storage scenario.
As a core product in CA-Fire’s  sprinkler lineup, the CHSAK-Z161-68°C Q3 is designed to control fire spread efficiently, with a lower required water supply pressure compared to early suppression fast response (ESFR) sprinklers. This industrial fire sprinkler is compatible with dry and pre-action fire protection systems, offering flexibility for diverse installation requirements. Whether protecting manufacturing plants, processing facilities, or industrial workshops, this industrial sprinkler head delivers reliable fire suppression while minimizing water damage to valuable equipment and infrastructure. All our industrial sprinkler products comply with international standards set by NFPA, UL, and FM, ensuring safety and compliance for every project.

Key Features of the CHSAK-Z161-68°C Q3 Industrial Sprinkler

The CHSAK-Z161-68°C Q3 non-warehouse special application industrial sprinkler is built with industrial-grade durability and performance at its core, incorporating advanced features to meet the unique fire protection needs of non-warehouse industrial environments. Every industrial fire sprinkler undergoes rigorous quality control testing at CA-Fire’s state-of-the-art facility in Quanzhou, China, ensuring it meets the highest standards of reliability and efficiency. Below are the standout features of this premium industrial sprinkler head:
  1. Specialized Non-Warehouse Design: This industrial sprinkler is optimized for non-warehouse industrial settings, with a focus on controlling fire spread in facilities such as manufacturing plants, processing centers, and industrial workshops.
  2. Large Flow Coefficient: The CHSAK-Z161-68°C Q3 industrial fire sprinkler boasts a high flow coefficient (K=161), delivering a powerful water output to quickly suppress fires in high-risk industrial areas.
  3. Flexible Installation Options: The industrial sprinkler head supports both upright and pendant installation methods, adapting to the layout and structure of diverse industrial facilities for comprehensive fire protection coverage.
  4. Low Working Pressure Requirement: Compared to ESFR sprinklers, this industrial sprinkler operates at a lower minimum working pressure, reducing the demand on fire water supply systems and lowering installation costs.
  5. Minimal Obstruction Impact: The design of this industrial fire sprinkler minimizes the impact of obstacles on water distribution, ensuring effective fire suppression even in facilities with complex equipment layouts.
  6. Durable Construction: Crafted with high-quality materials, the CHSAK-Z161-68°C Q3 industrial sprinkler is resistant to corrosion and wear, ensuring long-term performance in harsh industrial environments.
  7. Compliance with Global Standards: This industrial sprinkler head meets the requirements of international fire safety standards, including NFPA 13 (Standard for the Installation of Sprinkler Systems), UL certification, and FM approval, guaranteeing safe and reliable operation.
  8. Wide Application Compatibility: Suitable for use in dry and pre-action fire protection systems, this sprinkler offers versatility for various industrial fire protection needs.

CHSAK-Z161-68°C Q3 Industrial Sprinkler Specification

CA-Fire’s CHSAK-Z161-68°C Q3 non-warehouse special application industrial sprinkler (industrial fire sprinkler) is engineered with precise specifications to ensure optimal performance in non-warehouse industrial settings. Every technical parameter is carefully calibrated to meet the unique fire protection requirements of industrial facilities, providing reliable and efficient fire suppression. Below is the detailed technical specification of the CHSAK-Z161-68°C Q3 industrial sprinkler head:
Specification Details
Model Number CHSAK-Z161-68°C Q3
Product Type Non-Warehouse Special Application Industrial Sprinkler
Core Function Fire spread control in non-warehouse industrial environments
Nominal Operating Temperature 68°C
Flow Coefficient (K) 161
Maximum Ceiling Height 7.5m
Installation Methods Upright, Pendant
Minimum Working Pressure (MPa) 0.15
Installation Spacing (m) 2.4 – 3.7
Connection Thread R1
Compatible Fire Systems Dry systems, Pre-action systems
Applicable Medium Water
Operating Temperature Range (°C) 4 – 70
Compliance Standards NFPA 13, UL, FM

Customization for CHSAK-Z161-68°C Q3 Industrial Sprinkler

At CA-Fire, we understand that every industrial fire protection project has unique requirements. That’s why we offer customization options for the CHSAK-Z161-68°C Q3 industrial sprinkler (industrial fire sprinkler) to tailor it to your specific needs. Our engineering team can adjust parameters such as the operating temperature, connection thread, and flow coefficient to align with your facility’s fire risk level, equipment layout, and water supply system. Whether you need an industrial sprinkler head for a high-temperature manufacturing environment or a facility with unique installation constraints, we can deliver a customized solution that meets NFPA standards and your project’s specific requirements. All custom industrial sprinkler products undergo the same rigorous testing and quality control as our standard line, ensuring uncompromising performance and reliability.

Applications of the CHSAK-Z161-68°C Q3 Industrial Sprinkler

The CHSAK-Z161-68°C Q3 non-warehouse special application industrial sprinkler (industrial fire sprinkler) is a versatile fire protection solution designed for a wide range of non-warehouse industrial settings. Its specialized design, low working pressure requirement, and flexible installation options make it ideal for environments where standard sprinklers may not provide adequate fire suppression. The key applications of this industrial sprinkler head include:
  • Manufacturing Plants: Protecting production lines, equipment areas, and storage zones in manufacturing facilities such as automotive plants, electronics factories, and machinery workshops.
  • Processing Facilities: Fire protection for chemical processing plants, food processing facilities, and pharmaceutical manufacturing centers, where fire risks are heightened by flammable materials or high-temperature operations.
  • Industrial Workshops: Safeguarding workshops with complex equipment layouts, such as metalworking shops, woodworking facilities, and textile mills.
  • Power Generation Facilities: Protecting auxiliary areas of power plants, including turbine rooms, boiler houses, and maintenance workshops.
  • Chemical Storage Areas: Fire suppression for small to medium-sized chemical storage zones in non-warehouse industrial settings, where quick fire control is critical to prevent chemical reactions and spread.
  • Logistics and Distribution Centers: Non-warehouse logistics facilities with irregular storage layouts, such as sorting centers and distribution hubs.
  • Automotive Facilities: Protecting automotive assembly plants, repair workshops, and parts storage areas.

Why Choose CA-Fire’s CHSAK-Z161-68°C Q3 Industrial Sprinkler?

With over a decade of experience in the fire protection industry, CA-Fire Protection is a trusted manufacturer of high-quality industrial sprinkler (industrial fire sprinkler) systems, serving customers worldwide. Our CHSAK-Z161-68°C Q3 non-warehouse special application industrial sprinkler head is backed by our commitment to quality, innovation, and customer satisfaction, making it the preferred choice for industrial fire protection projects. Here are the key reasons to choose CA-Fire for your industrial sprinkler needs:
  1. Expert Engineering and Manufacturing: Our industrial sprinkler products are designed by a team of fire protection experts with extensive industry experience, using advanced production technology and high-quality materials. Every CHSAK-Z161-68°C Q3 industrial fire sprinkler is manufactured to the highest standards, ensuring reliable performance and long service life.
  2. Comprehensive Fire Protection Solutions: As a one-stop provider, we offer not just industrial sprinkler heads, but a full range of fire safety equipment, including foam extinguishing systems, fire valves, and fire hydrants, allowing you to source all your fire protection needs from a single, trusted supplier.
  3. Global Standard Compliance: Our CHSAK-Z161-68°C Q3 industrial sprinkler complies with international standards such as NFPA, UL, and FM, ensuring compatibility and compliance for projects worldwide. All our products are certified by national fire safety authorities and insured by PICC, providing an extra layer of assurance.
  4. Rigorous Quality Control: Every industrial sprinkler undergoes multiple quality control checks, including pressure testing, flow performance testing, and thermal sensitivity testing, to ensure it meets our strict quality standards. Our state-of-the-art quality control laboratory is equipped with advanced testing equipment to guarantee consistent performance.
  5. Proven Track Record: CA-Fire’s industrial sprinkler products have been installed in thousands of high-profile projects across Asia, Europe, and North America, including Beijing Daxing International Airport, Tencent Qingyuan Cloud Computing Data Center, and Shanghai South 翔印象城 MEGA. Our industrial fire sprinkler systems have a proven track record of reliable fire suppression in real-world scenarios.
  6. Customization and Technical Support: We offer customized industrial sprinkler solutions and professional technical support, from project design and product selection to installation guidance and after-sales service. Our team of technical experts is available to answer your questions and provide tailored recommendations to meet your specific fire protection needs.
  7. Competitive Pricing and Timely Delivery: As a direct manufacturer, we offer competitive pricing for our industrial sprinkler products without compromising on quality. Our efficient production and logistics system ensures timely delivery to customers worldwide, minimizing project delays.

Installation and Maintenance of the CHSAK-Z161-68°C Q3 Industrial Sprinkler

Proper installation and regular maintenance are essential to ensure the optimal performance of your CHSAK-Z161-68°C Q3 (industrial fire sprinkler). This industrial sprinkler head is designed for easy installation, compatible with standard fire water supply pipelines, and supports both upright and pendant mounting. For installation, we recommend following the guidelines outlined in NFPA 13 and consulting a qualified fire protection professional to ensure correct positioning and spacing.
To maintain the performance of your industrial sprinkler head, regular maintenance is required:
  • Quarterly Inspections: Check the industrial sprinkler for physical damage, corrosion, or obstruction; ensure the sprinkler head is free of dust, debris, and paint buildup that could affect its operation.
  • Annual System Testing: Conduct a comprehensive test of the fire protection system, including pressure testing and flow testing, to ensure the industrial fire sprinkler operates within the specified parameters.
  • Replacement of Worn Parts: Replace any damaged or worn components of the industrial sprinkler immediately to avoid performance issues during a fire emergency.
  • Professional Servicing: For complex industrial sprinkler systems, we recommend annual professional servicing by CA-Fire’s technical team to ensure full system functionality and compliance with safety standards.
CA-Fire provides a detailed installation and maintenance manual with every CHSAK-Z161-68°C Q3 purchase, and our technical support team is available to assist you with any questions or concerns.

Contact CA-Fire for Your Industrial Sprinkler Needs

If you are looking for a reliable, high-performance industrial sprinkler (industrial fire sprinkler) for your non-warehouse industrial facility, CA-Fire Protection is your trusted partner. Our CHSAK-Z161-68°C Q3 non-warehouse special application sprinkler head is engineered to deliver exceptional fire suppression performance, comply with global standards, and meet the unique needs of industrial environments. We are committed to providing fire protection solutions that safeguard life and property, and we serve customers worldwide with professionalism and integrity.
To learn more about the CHSAK-Z161-68°C Q3 sprinkler, request a product quote, or discuss your customized fire protection needs, please contact us using the details below. Our sales team will respond to your inquiry promptly and provide you with all the information you need to make the right choice for your project:
  • Email: sales@ca-fire.com
  • Mobile: +86 13400715622
  • WhatsApp: +86 18150362095
  • WeChat: 404863577
  • Website: https://www.ca-fire.com
CA-Fire Protection – Your Global Partner for Premium Fire Protection Equipment. Our sprinkler and industrial fire sprinkler systems are crafted with passion and precision, ensuring peace of mind for every industrial project, every time.
Specification Details
Model Number CHSAK-Z161-68°C Q3
Product Type Non-Warehouse Special Application Sprinkler
Core Function Fire spread control in non-warehouse industrial environments
Nominal Operating Temperature 68°C
Flow Coefficient (K) 161
Maximum Ceiling Height 7.5m
Installation Methods Upright, Pendant
Minimum Working Pressure (MPa) 0.15
Installation Spacing (m) 2.4 – 3.7
Connection Thread R1
Compatible Fire Systems Dry systems, Pre-action systems
Applicable Medium Water
Operating Temperature Range (°C) 4 – 70
Compliance Standards NFPA 13, UL, FM