CA-FIRE Protection · Foam Bladder Tank Series
Horizontal Foam Bladder Tank — PHYM Series
Low-profile hydraulic foam proportioning · 0.5–13.0 m³ · 4–360 L/s · DN80–DN250 · ±0.3% Accuracy · No Electricity · NFPA 11 / GB · Underground & Shipboard Installations
PHYM Series
4–360 L/s
0.5–13.0 m³
Low Profile
No Electricity
NFPA 11
ISO 9001
PHYM Series Horizontal Foam Bladder Tank — saddle-mounted, low-profile configuration
Product Overview
Horizontal Foam Bladder Tank
PHYM Series · Low-Profile Pressure Proportioning
Tank Volume
0.5–13.0 m³
Flow Range
4–360 L/s
Pipe Diameter
DN80 – DN250
Working Pressure
0.6–1.2 MPa
Mix Accuracy
±0.3%
Mixing Ratio
3% or 6%
Test Pressure
1.5 MPa
Electricity
None required
NFPA 11
NFPA 16
GB 50151
ISO 9001
CE
Key Features
📐
Low-Profile Design — Installs Where Vertical Tanks Cannot
The defining advantage of the horizontal foam bladder tank is its reduced installed height.
Saddle-mounted on a floor-level foundation, the PHYM series fits inside
underground pump rooms, basement plant rooms,
shipboard suppression spaces and any location where ceiling height prevents
a vertical tank. Weight is distributed across two saddle points — reducing foundation
load concentration compared to a vertical base-mounted unit.
Underground · Basement · Shipboard
🎯
±0.3% Mixing Accuracy — Across Full 4–360 L/s Range
The PHYM proportioner maintains foam concentrate delivery within
±0.3% of the rated 3% or 6% mixing ratio across the full operating
flow range — passively, without electronic controls or operator intervention.
The bladder's hydraulic balance mechanism holds the ratio stable across the complete
0.6–1.2 MPa working pressure range, exceeding
NFPA 11
proportioning accuracy requirements.
Exceeds NFPA 11 · No Electronics
🔒
Bladder Isolation — Concentrate Preserved & Reusable
The internal rubber bladder physically separates foam concentrate from the pressurised
water supply at all times — preventing water ingress into the concentrate, which is the
primary cause of concentrate degradation in open-tank proportioning systems.
After a partial activation, unused concentrate remains in the bladder in full condition,
ready for reuse at the next activation without replacement.
Foam concentrate shelf life: typically 10–25 years depending on type.
No Contamination · 10–25yr Shelf Life
⚙️
Fully Customisable — Volume, Pipe Size & Flow to Order
CA-FIRE configures each PHYM horizontal foam bladder tank to the
hydraulic model of your suppression system. Tank volume (0.5–13.0 m³), main pipe
diameter (DN80–DN250) and proportioner flow rating (4–360 L/s) are all adjustable —
matching required discharge duration and peak flow exactly per
NFPA 11,
NFPA 16 or GB 50151. Free hydraulic sizing support included
for every project.
0.5–13.0 m³ · DN80–DN250 · Free Sizing
What's Included — Complete System Supply
Every CA-FIRE horizontal foam bladder tank is supplied as a complete, ready-to-install system. No sourcing individual components from separate suppliers.
1
Pressure Vessel (Horizontal)
Carbon steel body, fusion-bonded epoxy internal lining. Hydrostatically tested to 1.5 MPa before despatch.
2
Internal Rubber Bladder
EPDM / NBR rubber bladder — physically separates foam concentrate from water supply. Replaceable in-situ.
3
Proportioner Assembly
Hydraulic in-line proportioner — no electricity, no moving electronics. Calibrated to ±0.3% at rated flow.
4
Isolation Valves
Full-bore inlet, outlet and bypass isolation valves. Allows safe maintenance without system shutdown.
5
Pressure Gauges & Safety Valve
Inlet and outlet pressure gauges, safety pressure relief valve pre-set to system design pressure.
6
Level Indicator & Documentation
Foam concentrate level indicator. Full system documentation: datasheet, test certificate, installation manual and operation guide.
PHYM Series — Model Parameters & Specifications
Select the PHYM model matching your system design flow rate. Tank volume and pipe diameter are customised to each project — contact CA-FIRE for hydraulic sizing at no charge.
| Model | Inlet Flow (L/s) 3% Ratio |
Inlet Flow (L/s) 6% Ratio |
Foam Output (L/s) 3% Ratio |
Foam Output (L/s) 6% Ratio |
Mixed Solution (L/s) | Working Pressure (MPa) | Tank Volume (m³) | Main Pipe DN |
|---|---|---|---|---|---|---|---|---|
| PHYM 4 | 4 | 4 | 0.12 | 0.24 | 4–120 | 0.6–1.2 | 0.5–13.0 | DN80–DN250 |
| PHYM 8 | 8 | 8 | 0.24 | 0.48 | 4–120 | 0.6–1.2 | 0.5–13.0 | DN80–DN250 |
| PHYM 16 | 16 | 16 | 0.48 | 0.96 | 4–120 | 0.6–1.2 | 0.5–13.0 | DN80–DN250 |
| PHYM 24 | 24 | 24 | 0.72 | 1.44 | 4–120 | 0.6–1.2 | 0.5–13.0 | DN80–DN250 |
| PHYM 32 | 32 | 32 | 0.96 | 1.92 | 4–120 | 0.6–1.2 | 0.5–13.0 | DN80–DN250 |
| PHYM 48 | 48 | 48 | 1.44 | 2.88 | 4–120 | 0.6–1.2 | 0.5–13.0 | DN80–DN250 |
| PHYM 64 | 64 | 64 | 1.92 | 3.48 | 4–120 | 0.6–1.2 | 0.5–13.0 | DN80–DN250 |
| PHYM 76 | 76 | 76 | 2.28 | 4.56 | 4–120 | 0.6–1.2 | 0.5–13.0 | DN80–DN250 |
| PHYM 100 | 100 | 100 | 3.00 | 6.00 | 4–360 ★ | 0.6–1.2 | 0.5–13.0 | up to DN250 |
| ★ Mixed solution range 4–120 L/s standard; up to 360 L/s available on PHYM 100 and custom configurations. All tank volumes and pipe diameters customisable to project hydraulic design. Contact CA-FIRE for free sizing. | ||||||||
Horizontal vs. Vertical Foam Bladder Tank — Which to Specify?
Both configurations deliver identical proportioning performance (±0.3%). The decision is driven entirely by the physical constraints of the installation space.
| Parameter | Horizontal Bladder Tank (PHYM) — This Product | Vertical Bladder Tank (PHY) |
|---|---|---|
| Installed Height | ✓ Low — fits restricted headroom | Higher — requires ceiling clearance |
| Floor Footprint | Larger — longer saddle-mounted footprint | ✓ Compact — smaller floor area |
| Underground / Basement Rooms | ✓ Preferred — low profile fits | — Less suitable |
| Shipboard Installation | ✓ Standard choice for vessels | — Space constraints usually prohibit |
| Above-Ground Pump Rooms | Suitable | ✓ Preferred — maximises floor space |
| Max Flow Rate | 4–360 L/s — widest range | 8–120 L/s |
| Tank Volume Range | 0.5–13.0 m³ | 0.5–13.0 m³ |
| Proportioning Accuracy | ±0.3% | ±0.3% |
| Mixing Ratio | 3% or 6% | 3% or 6% |
| Product Link | This page ↑ | View Vertical Tank → |
Typical Applications — Horizontal Foam Bladder Tank
| Application | Why Horizontal? | Typical PHYM Model | Standard |
|---|---|---|---|
| Petrochemical Tank Farms | High flow demand (up to 360 L/s); often installed in low-ceiling pump houses | PHYM 76 / PHYM 100 | NFPA 11 |
| Aircraft Hangars | Large-volume foam-water deluge systems; basement pump room installation common | PHYM 64 / PHYM 100 | NFPA 409 / NFPA 11 |
| Marine & Offshore (Tankers / FPSOs) | Deck-below-deck spaces; strict height constraints in engine rooms and cargo pump rooms | PHYM 8 – PHYM 48 | IMO MSC / SOLAS |
| Underground Pump Rooms | Low ceiling — only horizontal orientation fits; PHYM sits within standard basement floor-to-beam clearance | PHYM 16 – PHYM 48 | GB 50151 / NFPA 11 |
| Power Plant Transformer Bays | Often housed in low-profile equipment vaults; horizontal installation preferred by structural engineers | PHYM 16 – PHYM 32 | NFPA 15 / GB 50229 |
| Tunnel & Subway Infrastructure | Severely restricted headroom in tunnel cross-passages and equipment rooms | PHYM 8 – PHYM 24 | GB 50016 / NFPA 502 |
Frequently Asked Questions — Horizontal Foam Bladder Tank
What foam concentrates are compatible with the PHYM horizontal foam bladder tank?
The PHYM series is compatible with all standard foam concentrates: AFFF (Aqueous Film Forming Foam), AR-AFFF (Alcohol-Resistant AFFF), protein foam and synthetic foam at 3% or 6% mixing ratio. The internal bladder material (EPDM/NBR) is chemically resistant to all common concentrates. Confirm your specific concentrate with CA-FIRE at the time of order to verify compatibility.
How is the horizontal foam bladder tank different from a bladder tank proportioner system?
The horizontal foam bladder tank is a bladder tank proportioner system — a complete unit combining the pressure vessel, internal bladder, proportioner assembly, valves and instrumentation. It uses the differential pressure between the system water supply and the bladder interior to drive foam concentrate into the proportioner at the exact ratio required. No separate proportioner skid or additional equipment is needed — the PHYM is a self-contained proportioning device.
Does the horizontal foam bladder tank require any electrical power?
No. The PHYM series operates entirely on hydraulic pressure from the fire pump water supply. No electrical power, solenoid valves, sensors or control panels are required for proportioning operation. This makes the system inherently reliable in power-failure scenarios and simplifies installation — no electrical conduit to the tank.
What is the maximum flow rate of the horizontal foam bladder tank?
The PHYM 100 model reaches 360 L/s mixed solution flow — the highest in the CA-FIRE foam bladder tank range, and more than 3× the maximum 120 L/s of the vertical PHY series. This makes the PHYM series the only CA-FIRE option for large petrochemical tank farm systems and major aircraft hangars where peak design flow exceeds 120 L/s.
How long does foam concentrate last inside the bladder tank?
Foam concentrate stored inside a properly maintained bladder tank typically has a shelf life of 10–25 years depending on concentrate type. AFFF and synthetic concentrates generally achieve 10–15 years; protein-based concentrates vary by formulation. Because the bladder physically isolates concentrate from water at all times, no water dilution or contamination occurs during storage — the concentrate quality is preserved. Follow the foam concentrate manufacturer's recommended inspection schedule.
Is the PHYM horizontal foam bladder tank NFPA 11 compliant?
Yes. The PHYM series is designed and tested in compliance with NFPA 11 (Low-, Medium- and High-Expansion Foam) and NFPA 16 (Foam-Water Sprinkler Systems), as well as China's GB 50151 national standard. Full compliance documentation, test certificates and submittal datasheets are provided with every unit for authority review. See our download centre for available technical documents.
Related Products
PHY Series · Compact Footprint
Vertical Foam Bladder Tank
Upright configuration for above-ground fire pump rooms where floor space is constrained but ceiling height is available. Flow range 8–120 L/s across 6 PHY models.
View Vertical Tank →
Mobile Unit · First Response
Portable Foam Fire Extinguishing System
Self-contained wheeled or skid-mounted foam suppression unit. No fixed pipework required. Deploys in minutes for first response and temporary protection.
View Portable System →
Deluge System Component
Deluge Valve
CA-FIRE deluge valves paired with horizontal foam bladder tanks for foam-water deluge nozzle systems on tank farms, hangars and process areas.
View Deluge Valves →
Foam Discharge Device
Fire Monitor
Fixed and oscillating foam/water monitors for petrochemical tank farm and marine deck protection — commonly supplied with portable and horizontal bladder tank systems.
View Fire Monitors →
Isolation Valve
Gate Valve (OS&Y / NRS)
Full-bore PN16 flanged and grooved gate valves for foam system supply and discharge mains — DN50 to DN400. NFPA 13 compliant rising-stem OS&Y models available.
View Gate Valves →
Full Range · 3 Products
All Foam Bladder Tank Models
Compare all CA-FIRE foam bladder tank configurations — horizontal, vertical and portable — with full specification comparison and selection guide.
View All Models →
Get a Quote — Horizontal Foam Bladder Tank
PHYM Series · 0.5–13.0 m³ · 4–360 L/s · NFPA 11 / GB · Free Hydraulic Sizing · Factory Direct.
Send your system flow rate, tank volume and installation constraints — CA-FIRE returns a sizing recommendation and project price within 24 hours.
📧 Send Enquiry Now
Send your system flow rate, tank volume and installation constraints — CA-FIRE returns a sizing recommendation and project price within 24 hours.
💬 WeChat: 404863577